A-A-50757
b. Gain instability. The gain instability of the recorder is ±0.1% of reading for 24 hours of running, ±0.05% of reading per degree celsius, and ±0.05% of reading for ±l0% line voltage change.
4. Specify type and size.
a. Design and construction. Unless otherwise specified herein, the equipment shall comply with the Type III design and construction requirements specified in MIL-T-28800.
b. Solid state construction. The equipment shall be of solid-state modular miniaturized construction. Electron tubes shall not be used.
c. Receptacle and connector mounting. All AC/DC input connectors are provided on barrier strip for jumper wire assembly. The connectors shall comply with MIL-T-28800 3.4.1.5.2.
d. Signal adjustment. All output signals shall be externally adjustable 100 to 40%.
e. Accessibility. The equipment shall be constructed so subassemblies and chassis components can he removed without removing any other hardware subassemblies, printed circuit card or component.
f. Input power switch. The input power switch shall comply with Type III input switch requirements of MIL-T-28800, except that the switch shall break both sides of the power source, but not break the earth ground conductor circuit.
g. Fuses or circuit breakers. Fuses or circuit breakers shall comply with Type III requirements of MIL-T-28800. Input power line shall be equipped with-fuses or circuit breakers.
5. Dimensions, weight and mechanical stability.
a. Weight. The unpacked weight of the power supply, including all accessories, shall be 105 pounds nominal.
b. Dimensions. The dimensions of the four-channel recorder accessories, installed in the Style F enclosure as referenced in MIL-T-2800 shall be 19.31 inches in width, 17.22 inches in height and 14.75 inches in depth.
CERTIFICATION. The contractor shall certify that the product offered meets the salient characteristics of this description, and that the product conforms to the producers own drawings, specifications, standards and quality assurance practices. Bid samples from bidders will be tested in accordance with the salient characteristics of this Commercial Item Description at San Antonio ALC, Kelly APB, TX 78241.
OPERATIONAL INSTRUCTIONS/MAINTENANCE MANUAL. The contractor shall prepare an operator’s manual according to the provisions-of MIL-M-38797 for all equipment delivered under terms of this contract.
For Parts Inquires submit RFQ to Parts Hangar, Inc.