INCH-POUND
MIL-DTL-16034/13A
13 March 2008
SUPERSEDING
MIL-M-16034/13
2 January 1953
DETAIL SPECIFICATION SHEET
VOLTMETERS, AC, PORTABLE, 0.75-PERCENT ACCURACY CLASS
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-16034.
REQUIREMENTS:
VOLTS, A.C.
Single range
Multiple range
15
800
700/300/150
FULL-SCALE RANGE
30
150
300
ITEM
REQUIREMENTS
Scale length
3.2 inches min
Position influence (balance)
1 percent of scale length, max change
Initial accuracy
0.75 percent max error
Damping factor
3 min
Response time
3.4 seconds max
Power consumption
10 VA max: voltmeters, 150-volt single range
20 VA max: voltmeters, any range except 150-volts single range
Frequency range
1 percent max change at 25 and 125 cycles
Frequency influence
0.2 percent max change at 54 and 66 cycles
Heat effect at 65 °C
2 percent max change at 65 °C
0.5 percent max permanent change
Temperature influence
0.5 percent max change
1.25 percent max change at 0 °C
Low-temperature exposure
0.5 percent max permanent change
Sustained overload
1 percent of scale length, max temporary zero shift
0.5 percent of scale length, max permanent zero shift
0.33 percent max permanent change in indication
AMSC N/A
FSC 6625