a. Rack mounting. Rack mounting capability shall be available as an option for the equipment specified herein.
b. Tilt-Bail Handle. A tilt-bail handle shall be provided in lieu of the hinged metal handles in accordance with MIL-T-28800. Exception to this paragraph may be acceptable as this is not a prime consideration of the equipment.
c. Reusable Pouch or Container. An attached accessory pouch may be used for storage of all supplied accessories in lieu of front-cover storage.
7. Marking and Identification.
a. Marking. The visible surface adjacent to panel facilities such as variable controls, indicators, jacks, connectors and fuse holder(s), shall be marked with a suitable word, phrase, or abbreviation hereof, indicating the purpose or use of the part.
(1) Panel Marking. The front panel marking shall comply with the type III parts, materials, and processes panel marking requirements of MIL-T-28800; however, marking identification processes other than the type III requirements specified in MIL-T-28800 may be used, provided the marking and identification processes are capable of passing the front panel marking test when tested in accordance with this CID.
b. Items to be Marked (if applicable).
(1) Volume and Weight (including accessories) shall be marked on three external surfaces of the enclosure.
(2) The type designation of the AN nomenclature of the SNMS shall be stenciled on the exterior or main frame on at least three adjacent surfaces, on the transient case on two opposite sides. Marking shall be in block letters approximately 2 inches in height.
8. Environmental Requirements.
a. Temperature Requirements. Unless otherwise specified herein, the equipment shall meet its specified performance characteristics and other requirements when subjected to the class 5 temperature requirements specified by MIL-T-28800 and as listed below.
(1) Non-Operating Temperature. The equipment shall meet its performance and accuracy requirements in an non-operating environment of -40 C to +650 C.
(2) Operating Temperature. The equipment shall meet its performance and accuracy requirements in an operating environment of O C to 50 C.
b. Humidity Requirements. The equipment shall meet its required performance and accuracy requirements under humidity requirements for class equipment as specified by MIL-T-28800.