A-A-50682
(2) Extension Cables. Extension Cables shall be available to extend the distance between the scalar network analyzer and the detector or bridge to a maximum of 200 ft. without degradation of performance.
(3) Directional Bridge. A directional bridge shall be provided which meets the following minimum requirements.
A. Frequency Range: 0.01 to 26.5 Gigahertz
B. Directivity: At least 35 dB C. Input Impedance: 50 ohms
D. Test Port Connector: Type N
(4) Waveguide Adapters: Two sizes of waveguide adapters shall be provided which meet the following minimum requirements.
A. Waveguide Size WR 112:
(1) Frequency Range: 7.05 GHz - 10.0 GHz
(2) SWR: Not more than 1.25
B. Waveguide Size WR 90:
(1) Frequency Range: 8.20 GHz - 12.4 GHz
(2) SWR: Not more than 1.25
14. Calibration Interval. After calibration, the equipment shall meet each performance requirement within the tolerances specified for a period of at least 9 months, based on an operating time of 1500 hours.
Packaging, packing, and marking. The items shall be packed in accordance with normal commercial practice and packed to assure acceptance by common carrier and provide product protection against loss and damage during multiple shipments, handling, and storage. The shipping container shall be in compliance with national motor freight classification and uniform freight classification. Preservation, packaging, packing, labeling, and marked shall be a specified in the contract or order.
Certification. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this description and that the product conforms to the producer's own drawings, specifications, and standards and quality assurance practices and is the same product offered for sale in the commercial marketplace. Small businesses that cannot offer