A-A-50682
(1) Setting, storage, and recall of front panel settings. (2) Storage and recall of reference waveforms.
(3) Marker control/positioning.
(4) Internal diagnostic and calibration routines.
n. Waveform Transfer. The equipment shall provide the capability to transmit and receive digitized waveforms via IEEE-488-1978 interface. Waveforms sent to the equipment shall be treated as reference waveforms and shall be loaded into the appropriate reference waveform memory. In addition, waveform scaling data shall also be transferable over the GPIB interface and displayable on the CRT with the reference waveform(s).
o. Plotter Output. The equipment shall provide the capability to directly drive an external X-Y or IEEE-488-1978 plotter without the requirement for an instrument controller. This capability shall allow the generation of hard copy from displayed waveforms.
p. Printer Output. The equipment shall provide the capability to directly drive an external or an IEEE-488-1978 printer or X-Y Plotter without the requirement for an instrument controller. This capability shall allow the generation of hard copy from displayed waveforms.
q. Required Accessories. The following (minimum) accessories shall be required with each deliverable equipment. The accessories' shall be compatible with the vendor's perspective equipment.
Operator's Manual(s) Spare fuse(s)
US Power Cord (at least 2.0m, 6 ft.) Three (3) RF Diode Detectors Direction Bridge
Two (2) Waveguide Adapters (Size [EIA] WR 112) Two (2) Waveguide Adapters (Size [EIA] WR 90) Extension Cables
(1) RF Diode Detector. The RF Diode Detector shall meet the following minimum requirements. A. Frequency Range: 0.01 to 26.5 Gigahertz
B. Maximum Power Input at least +20 dBm (lOOmW)
C. Input Impedance shall be 50 ohms nominal
9
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business