A-A-50728A
d. Resolution. Resolution for the equipment shall equal or better the following:
Signal level separation 0 dB 20 dB 50 dB
25 |
MHz |
250 |
KHz |
350 |
KHz |
500 |
KHz |
10 |
MHz |
100 |
KHz |
150 |
KHz |
200 |
KHz |
3 |
MHz |
30 |
KHz |
40 |
KHz |
50 |
KHz |
300 |
KHz |
5 |
KHz |
10 |
KHz |
15 |
KHz |
60 |
KHz |
1 |
KHz |
2 |
KHz |
4 |
KHz |
4 |
KHz |
100 |
Hz |
200 |
Hz |
500 |
Hz |
3. Level.
a. Range. The equipment shall be capable of displaying levels in the following ranges:
Total -109 dBm to +10 dBm (for zero level on display) Display 60 dB logarithmic (linear dB scale)
+40 dB to -20 dB (referred to 0 dB reading on levelmeter)
b. Accuracy. The equipment shall have the same accuracy as reflected for the level meter in para 3.13.2.
c. Frequency response. The frequency response for the equipment shall be within ±0.1 dB for full frequency span of 1 KHz to 25 MHz.
d. Display linearity. The equipment shall have a vertical linearity of ±0.5 dB in the dB/cm mode and ±2 dB in the 10 dB/cm mode.
4. IF Bandwidths. The equipment shall have the following sweep widths.
at 3 |
dB |
|||
25 |
MHz |
10 MHz and 3 MHz |
5 |
KHz |
300 |
KHz |
1.5 |
KHz |
|
60 |
KHz |
400 |
Hz |
|
4 |
KHz |
45.0 |
Hz |
5. Sweep Rate. The equipment shall be capable of providing the following sweep rates:
Sweep widths Sweep rate
25 |
MHz |
0.9 Hz (2500 MS period) |
10 |
MHz |
1.0 Hz (1000 MS period) |
3 |
MHz |
|
300 |
KHz |
2.2 Hz (450 MS period) |
60 |
KHz |
|
4 |
KHz |
0.5 Hz (2000 MS period) |