A-A-50760
30 May 86
COMMERCIAL ITEM DESCRIPTION
SIGNAL GENERATOR
The General Services Administration has authorized the use of this Commercial Item Description
Scope. Rack mounted in the AN/APR-38 Test Set used to test/repair/align the APR-38 Intermediate Frequency Processor (IFP). The IFP is used by the system to compute angle of arrival information from the APR-38 receivers. The unit’s time of IF pulses is crucial to the total system’s operations
Salient characteristics
1. Frequency characteristics
a. Frequency range |
7.75 – 512 MHz in six bands |
||
|
Band 1 |
248 MHz – 512 MHz |
|
Band 2 |
124 MHz – 256 MHz |
||
Band 3 |
62 MHz – 128 MHz |
||
Band 4 |
31 MHz – 64 MHz |
||
Band 5 |
15.5 MHz – 32 MHz |
||
Band 6 |
7.75 MHz – 16 MHz |
||
b. Frequency vernier range |
> 300 ppm |
||
c. Frequency resolution |
Continuously tunable. Six digit frequency display with a least significant digit of 100 Hz (7.75 – 62 MHz) or 1kHz (62 – 512 MHz) |
||
d. Frequency accuracy |
|||
Locked mode |
± (0.05 of last digit time base accuracy) |
||
Unlocked mode |
± (last digit ± time base accuracy) |
||
e. Time base accuracy |
|||
Standard |
< ± 1 ppm after two hour warm up @ 250C |
||
Option |
< ± 0.1 ppm after two hour warm up @ 250C |
||
f. Frequency stability |
Lock |
unlocked |
|
Time (after two hr warm up) |
<1 ppm/24 hrs. |
<10 ppm/10 mins. |
|
Temperature (00C to 550C) |
<0.33 ppm/0C |
<60 ppm/0C |
|
|
(Option 0.03 ppm/0C) |
|
|
Line voltage (± 10% change) |
<1 ppm |
<10 ppm |
|
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.