A-A-50760
Load (open to short) |
None |
None |
Level change |
||
10 dB vernier |
None |
1 ppm |
10 dB steps |
None |
None |
Model change |
||
CW to AM |
None |
None |
CW to FM |
|
<150 ppm of carrier frequency |
g. Frequency lock hold range |
± 600 ppm or ± 100C min |
2. Spectral purity characteristics
a. Residual FM |
Mode |
CW |
FM |
||
Up to Max |
Pk Dev |
||||
Post |
300 Hz |
20 Hz |
300 Hz |
20 Hz |
|
Delection |
3 kHz |
15 kHz |
3 kHz |
15 kHz |
|
Bandwidth |
|
||||
248 – 512 MHZ |
<5Hz |
<15 Hz |
<9 Hz |
<30 Hz |
|
124 – 256 MHz |
<3 Hz |
<7 Hz |
<5 Hz |
<15 Hz |
|
7.75 – 126 MHz |
<2 Hz |
<5 Hz |
<3 Hz |
<8 Hz |
|
b. Spurious signals |
|
|
|
|
|
Harmonics |
> 30 dB below carrier |
||||
Sub-harmonics |
> 45 dB below carrier |
||||
Non-harmonics |
Not perceptible |
||||
c. Broadband noise |
130 dB below carrier is a 1 Hz bandwidth at maximum power level vernier position over entire frequency range |
3. RF Power output characteristics
a. Output power control range |
20 dBm (2.2V) to -146 dBm (0.01µV) in 10 dB steps with continuous adjustment between steps. Output level indicated on attenuator and meter calibrated in dBm and volts into nominal 50Ω load. |