MIL-DTL-16034B
(2) Initial accuracy
(3) Damping factor
(4) Response time
b.
The magnitude of the failure is limited to 1½ times the specified tolerance for the initial-accuracy test, and 2
times the specified tolerance for the other three tests.
4.3.3.2 Portable meters. No failure will be permitted on portable meters.
4.4 Conformance inspection. Conformance inspection will be performed at the place of manufacture by the
Government or under the direction of the Government.
4.4.1 Sampling procedure. At the discretion of the Government, conformance tests may be conducted by either
of the following methods or a combination of both:
a.
100 percent inspection.
b.
Statistical sampling and inspection in accordance with MIL-STD-1916. The classification of major and
minor defects for visual and mechanical inspection shall be as specified in table V.
4.4.2 Test routine. Meters shall be subjected to the tests specified in table IV, in the order listed.
4.4.3 Rejected meters. Rejected meters shall be returned to the contractor. Rejected meters may be reworked, if
possible, in such a manner as to remove all defects. Reworked meters shall be submitted for acceptance separately
from newly-produced meters.
13